Connect-Tek USB-8 Specifications Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
Section 4. USB Communications
25
Example Set HOST POLL TIMEOUT property Response (Hex):
Result Code
Data Len
Data
00
00
Example Get HOST POLL TIMEOUT property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
52
Example Get HOST POLL TIMEOUT property Response (Hex):
Result Code
Data Len
Prp Value
00
01
02
RESET DEVICE COMMAND
Command number: 0x02
Description: This command is used to reset the device. This command can be used to
make previously changed properties take affect without having to unplug and
then plug in the device. When the device resets, it automatically does a USB
detach followed by an attach. After the host sends this command to the device
it should close the USB port, wait a few seconds for the operating system to
handle the device detach followed by the attach and then re-open the USB
port before trying to communicate further with the device.
Data structure: No data is sent with this command
Result codes: 0 (success)
Example Request (Hex):
Cmd Num
Data Len
Data
02
00
Example Response (Hex):
Result Code
Data Len
Data
00
00
Page view 30