Connect-Tek USB-8 Specifications Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
Section 4. USB Communications
23
Example Set TRACK ID ENABLE property Request (Hex):
Cmd Num
Data Len
Prp ID
Prp Value
01
02
04
95
Example Set TRACK ID ENABLE property Response (Hex):
Result Code
Data Len
Data
00
00
Example Get TRACK ID ENABLE property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
04
Example Get TRACK ID ENABLE property Response (Hex):
Result Code
Data Len
Prp Value
00
01
95
INTERFACE TYPE PROPERTY
Property ID: 0x10
Property Type: Byte
Length: 1 byte
Get Property: Yes
Set Property: Yes
Default Value: 0 (HID)
Description: The value is a byte that represents the devices interface type. The value can
be set to 0 for the HID interface or to 1 for the keyboard emulation interface.
When the value is set to 0 (HID) the device will behave as described in the
HID manual. When the value is set to 1 (keyboard emulation) the device will
behave as described in the keyboard emulation manual. This property should
be the first property changed because it affects which other properties are
available. After this property is changed, the device should be power cycled
before changing any other properties.
This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.
Example Set INTERFACE TYPE property Request (Hex):
Cmd Num
Data Len
Prp ID
Prp Value
01
02
10
01
Example Set INTERFACE TYPE property Response (Hex):
Result Code
Data Len
Data
00
00
Example Get INTERFACE TYPE property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
10
Page view 28